Friday, March 9, 2012

Pretransplant Donor-Specific HLA Class-I and -II Antibodies Are Associated with an Increased Risk for Kidney Graft Failure

Pretransplant risk assessment of graft failure is important for donor selection and choice of immunosuppressive treatment. We examined the relation between kidney graft failure and presence of IgG donor specific HLA antibodies (DSA) or C1q-fixing DSA, detected by single antigen bead array (SAB) in pretransplant sera from 837 transplantations. IgG-DSA were found in 290 (35%) sera, whereas only 30 (4%) sera had C1q-fixing DSA. Patients with both class-I plus -II DSA had a 10 yr graft survival of 30% versus 72% in patients without HLA antibodies (p < 0.001). No significant difference was observed in graft survival between patients with or without C1q-fixing DSA. Direct comparison of both assays showed that high mean fluorescence intensity values on the pan-IgG SAB assay are generally related to C1q-fixation. We conclude that the presence of class-I plus -II IgG DSA as detected by SAB in pretransplant sera of crossmatch negative kidney recipients is indicative for an increased risk for graft failure, whereas the clinical significance of C1q-fixing IgG-DSA could not be assessed due to their low prevalence (read more).

Tuesday, March 6, 2012

A Novel ELISPOT Assay to Quantify HLA-Specific B Cells in HLA-Immunized Individuals

Quantification of the humoral alloimmune response is generally achieved by measuring serum HLA antibodies, which provides no information about the cells involved in the humoral immune response. Therefore, we have developed an HLA-specific B-cell ELISPOT assay allowing for quantification of B cells producing HLA antibodies. We used recombinant HLA monomers as target in the ELISPOT assay. Validation was performed with human B-cell hybridomas producing HLA antibodies. Subsequently, we quantified B cells producing HLA antibodies in HLA-immunized individuals, non-HLA-immunized individuals and transplant patients with serum HLA antibodies. B-cell hybridomas exclusively formed spots against HLA molecules of corresponding specificity with the sensitivity similar to that found in total IgG ELISPOT assays. HLA-immunized healthy individuals showed up to 182 HLA-specific B cells per million total B cells while nonimmunized individuals had none. Patients who were immunized by an HLA-A2-mismatched graft had up to 143 HLA-A2-specific B cells per million total B cells. In conclusion, we have developed and validated a highly specific and sensitive HLA-specific B-cell ELISPOT assay, which needs further validation in a larger series of transplant patients. This technique constitutes a new tool for quantifying humoral immune responses (read more).

Very Early Recurrence of Anti-Phospholipase A2 Receptor-Positive Membranous Nephropathy After Transplantation

Membranous nephropathy is a common cause of adult nephrotic syndrome, with recent evidence suggesting that 70% of idiopathic disease is associated with anti-Phospholipase A2 receptor autoantibodies. We describe a 63-year-old man with membranous nephropathy who underwent a kidney transplant and developed recurrent membranous nephropathy with fine granular co-localization of Phospholipase A2 receptor and IgG evident on transplant biopsy on day 6 and elevated circulating levels of serum anti-Phospholipase A2 receptor autoantibody that declined over time in conjunction with improvement in the serum creatinine and urinary protein. This is a very early case of Phospholipase A2 receptor-associated recurrent membranous nephropathy with circulating anti-Phospholipase A2 receptor autoantibody, which supports the emerging evidence that idiopathic membranous nephropathy is an autoimmune disease (read more).

Monday, March 5, 2012

ABO-Incompatible Kidney Transplantation Enabled by Non-Antigen-Specific Immunoadsorption.

BACKGROUND: ABO-incompatible kidney transplantation performed after desensitization with antigen-specific immunoadsorption (IA) results in good outcomes. However, a unique single-use IA device is required, which creates high costs. METHODS: From August 2005 to August 2010, 19 patients were desensitized for ABO-incompatible living donor kidney transplantation. Six patients treated with a single-use antigen-specific IA device and 12 patients treated with a reusable non-antigen-specific IA device were analyzed. RESULTS: Six patients who received antigen-specific IA had a median of 5 IA treatments and 12 patients with non-antigen-specific IA had a median of 6 IA treatments preoperatively. Median average titer drop in Coombs technique was 1.2 in antigen-specific IA and 1.7 in non-antigen-specific IA. In two patients with antigen-specific IA and four patients with non-antigen-specific IA, additional plasmapheresis treatments were necessary for recipient desensitization. Despite six treatments with antigen-specific IA and 12 plasmapheresis treatments, one patient with a starting isoagglutinin titer of 1:1024 (Coombs) could not be transplanted. The 18-month graft survival rate for the 17 ABO-incompatible living donor kidney transplants was 100%. One male recipient who was desensitized with antigen-specific IA died 44 months after transplantation from sudden cardiac death with a serum creatinine of 1.2 mg/dL. At last follow-up, a median of 13 months after transplantation, median serum creatinine for 16 patients was 1.5 mg/dL, median glomerular filtration rate as estimated by the modification of diet in renal disease formula 54 mL/min/1.73 m, and median urinary protein-to-creatinine ratio 0.1, with no differences between treatments. CONCLUSIONS: A reusable non-antigen-specific IA device allows high number of treatments at reasonable cost, and at the same time might deplete human leukocyte antigen-alloantibodies (read more)

Saturday, March 3, 2012

MHC Class II Tetramers [BRIEF REVIEWS]

MHC class II tetramers have emerged as an important tool for characterization of the specificity and phenotype of CD4 T cell immune responses, useful in a large variety of disease and vaccine studies. Issues of specific T cell frequency, biodistribution, and avidity, coupled with the large genetic diversity of potential class II restriction elements, require targeted experimental design. Translational opportunities for immune disease monitoring are driving the rapid development of HLA class II tetramer use in clinical applications, together with innovations in tetramer production and epitope discovery (read more).

Friday, March 2, 2012

A pilot programme of organ donation after cardiac death in China

China's aims are to develop an ethical and sustainable organ transplantation system for the Chinese people and to be accepted as a responsible member of the international transplantation community. In 2007, China implemented the Regulation on Human Organ Transplantation, which was the first step towards the establishment of a voluntary organ donation system. Although progress has been made, several ethical and legal issues associated with transplantation in China remain, including the use of organs from executed prisoners, organ scarcity, the illegal organ trade, and transplantation tourism (read more).

Thursday, March 1, 2012

Clinical relevance of HLA donor-specific antibodies detected by single antigen assay in kidney transplantation

Clinical relevance of donor-specific antibodies (DSAs) detected by a single antigen Luminex virtual crossmatch in pre-transplant serum samples from patients with a negative cytotoxicity-dependent complement crossmatch is controversial. The aim of this study was to analyse the influence of a pre-transplant positive virtual crossmatch in the outcome of kidney transplantation. Methods. A total of 892 patients who received a graft from deceased donors after a negative cytotoxicity crossmatch were included. Presence of anti-human leucocyte antigen (HLA) antibodies was investigated using a Luminex screening assay and anti-HLA specificities were assigned performing a Luminex single antigen assay. Results. Graft survival was significantly worse among patients with anti-HLA DSA compared to both patients with anti-HLA with no DSA (P = 0.001) and patients without HLA antibodies (P < 0.001) using a log-rank test. No graft survival differences between anti-HLA with no DSA and no HLA antibodies patient groups were observed (P = 0.595). Influence of both anti-Class I and anti-Class II DSA was detected (P < 0.0001 in both cases). When the fluorescence values were stratified in four groups, no significant differences in graft survival were observed among the groups with fluorescence levels >1500 (global P < 0.05). Conclusions. The presence of preformed HLA DSA in transplanted patients with a negative cytotoxicity crossmatch is associated with a lower allograft survival. The detection of anti-HLA with no DSA has no influence in the graft outcome. Finally, there were no demonstrable effects of mean fluorescence intensity (MFI) values > 1500 on graft survival (read more).