Methods : Sera from 73 sensitized patients were analyzed by the generic IgGpan as well as IgG subclass specific SAB assays and correlated with the standard and an anti-human globulin (AHG) enhanced C1q test.
Results : Among 2,665 SABs with positive IgGpan results (mean fluorescence intensity [MFI]>500), strong complement-binding IgG1 and IgG3 subclasses accounted for a median of 99% (interquartile range, 76%–100%) of the total IgG amount. IgGpan MFI alone showed a very strong association with standard C1q positivity (r2=0.72), which was superior to a model including all IgG subclass MFI (r2=0.62). Combining all IgG subclass MFI and IgGpan MFI only marginally improved the prediction of standard C1q positivity compared with IgGpan MFI alone (Δr2=0.02). IgGpan MFI greater than 14,154 predicted standard C1q positivity, with 92% sensitivity and 96% specificity. Notably, 1,840 (93%) of the 1,974 C1q-negative SABs contained human leukocyte antigen antibodies with strong complement-binding IgG1 and IgG3 subclasses. Anti–human globulin significantly enhanced the signal in the C1q assay, but the association of AHG C1q positivity with IgGpan MFI was less strong (r2=0.51).
Conclusion : C1q binding on SAB is strongly associated with IgGpan MFI. IgG subclass information only marginally improves prediction of C1q binding likely because complement-binding IgG1 and IgG3 subclasses dominate regarding frequency and relative amounts. A negative C1q assay result does not indicate the absence of strong complement-binding IgG subclasses (read more) Print this post